The Fire Angel Wi-Safe2 Carbon Monoxide alarm FP1820W2 (previously W2-CO-10X) is a 10 year battery powered, sealed-for-life, wireless interlink CO alarm with advanced diagnostics that gives complete protection from CO poisoning in the home. It sends a wireless signal to all other Wi-Safe 2 products (such as the vibrating pad and strobe alert panel sold separately) when it detects CO, giving an early warning and better chance of escape.

This alarm will continuously detect for the presence of Carbon Monoxide and will sound a loud 85dB alarm to alert you in case of an emergency.

Carbon Monoxide (CO) is a colourless, odourless and tasteless gas often called the silent killer. CO can prove fatal, additionally it is thought that many CO incidents remain undetected, as low level poisoning symptoms can be mistaken for flu, nausea or headaches.

This alarm contains an advanced electrochemical sensor designed to accurately measure levels of CO. The micro-processor within the alarm has the ability to retain event history and report both the status of the alarm together with the last 10 alarm events, including when they happened and the CO level at the time of alarm. This is vital if a CO incident were to occur.

The W2-CO-10X  is easy to fit with an inbuilt bracket providing single or double point fixing options. It also has end of life indication and a ‘sleep-easy’ function which allows the end of life warning chirp to be temporarily silenced for 8 hours.

Key features include:

  • 10yr sealed for life battery back-up
  • Wireless interlink up to 50 x FireAngel smoke/ heat/ CO alarms on a single network
  • Sleep Easy- Low battery warning silence
  • Locate button - This will silence all wirelessly interlinked alarms except the initiating alarm which has sensed carbon monoxide / smoke 
  • Wireless range up to 200m in clear sight (we recommend not to exceed 35m as the maximum direct distance between smoke alarms inside a property)
  • Auto disable feature (for shipping)
  • Tamper proof integrated mounting plate
  • Size: 94mm (Height) 114mm (Width) x 39.5mm (Depth). Weight: 186g

     

IN WHICH ROOM SHOULD THE ALARM BE INSTALLED?
Ideally, an alarm should be installed in every room containing a fuel-burning
appliance and every sleeping room. Additional alarms may be installed to ensure that adequate warning is given for occupants in other rooms, in which they
spend considerable time whilst awake and from which they may not be able to hear an alarm in another part of the premises.

CO alarms should also be installed in any room which a flue passes through, even if the flue is fully enclosed or concealed. However, if there is a fuel-burning appliance in more than one room and the number of alarms is limited, the following points should be considered when deciding where best to put the alarm:
• Locate the alarm in a room containing a flueless or open-flued appliance.
• Locate the alarm in a room where the occupant(s) spend most time.
• If the domestic premises is a bedsit (a single room serving as both sitting and
bedroom) then the alarm should be put as far from the cooking appliances as possible and near to where the person sleeps.
• If the appliance is in a room not normally used (for example a boiler room), the alarm should be put just outside the room so that it may be heard more easily.

WHERE IN THE ROOM SHOULD I PLACE THE ALARM?
For alarms located in the same room as a fuel-burning appliance (for both wall and ceiling mounted alarms) the following applies:
• The alarm should be at a horizontal distance of between 1 m and 3 m from the
potential source.
• If there is a partition in a room, the alarm should be located on the same side of the partition as the potential source.
• Carbon monoxide alarms in rooms with sloped ceilings should be located at the
high side of the room.

In addition to the above the following must be observed if the alarm is located on a wall:
• It should be located close to the ceiling.
• It should be located at a height greater than the height of any door or window.
• It should be at least 150 mm from the ceiling.

If the alarm is located on the ceiling:
• It should be at least 300 mm from any wall and any ceiling obstruction e.g. light fittings.
Alarms located in sleeping rooms and in rooms remote from a fuel-burning
appliance should be located relatively close to the breathing zone of the occupants.

The W2-CO-10X  is certified to BS EN 50291-1:2010 and BS EN 50291-2:2010.

Approx size: 94 x 114 x 40mm.

Write a review

Please login or register to review

FireAngel Wi-Safe2 FP1820W2 Interlinked Wireless Carbon Monoxide alarm

  • Brand: FireAngel
  • Product Code: PLU210
  • Availability: In Stock
  • €83.87


Related Products

Bellman Visit Fire Safety Bundle with Visit Alarm Clock, Smoke Detector and Bed Shaker

Bellman Visit Fire Safety Bundle with Visit Alarm Clock, Smoke Detector and Bed Shaker

The Bellman Visit Safe Bundle is a fire alerting solution that comes complete and ready to use. It i..

€440.48

FireAngel Wi-Safe2 Interlinked Wireless Smoke Alarm System Basic Starter Pack

FireAngel Wi-Safe2 Interlinked Wireless Smoke Alarm System Basic Starter Pack

Wi-Safe2 basic system pack - consists of Wi-Safe2 strobe & vibrating pad alert FS1552W2(W2-SVO..

€234.79

FireAngel Wi-Safe2 Interlinked Wireless Thermoptek smoke alarm head, WST-630 with 5+ year life battery

FireAngel Wi-Safe2 Interlinked Wireless Thermoptek smoke alarm head, WST-630 with 5+ year life battery

A 5+ year, battery powered, sealed-for-life, wireless interlink smoke alarm with groundbreaking Ther..

€84.57

”twitter_icon”